  • Abstracts - Problem of Transcutaneous Bilirubinometry
    and only five false positive determinations 3 The positive predictive value for the TcB measurements was 58 This implies that in our population an infant with a TcB index greater than or equal to 24 has a 58 chance of having a serum bilirubin concentration greater than 12 9 mg 100 ml The negative predictive value was 100 Thus a negative test will correctly predict the absence of hyperbilirubinemia in

    Original URL path: http://www.clinlab.ru/tm/bilirub/65.%20Maisels.htm (2014-12-29)
    Open archived version from archive


  • Abstracts - Problem of Transcutaneous Bilirubinometry
    aim of this study was to analyse clinical usefulness of transcutaneous bilirubinometry as a noninvasive screening test in evaluating neonatal jaundice The material consisted of 106 full term infants in which 130 meter readings were performed A Minolta Air Shields Jaundice Meter 101 was used Meter readings were compared with serum bilirubin measurements from these infants correlation ratio was 0 56 After analysing the clinical data the conclusion was that

    Original URL path: http://www.clinlab.ru/tm/bilirub/67.%20Mo.htm (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    and serum Br photoisomers in two groups of 5 jaundiced newborn infants treated by intensive phototherapy IP one with blue light and the other with green light Cutaneous Br was measured with a transcutaneous jaundice meter and photoisomers were measured by HPLC Cutaneous Br decreased in the two groups as soon as IP began and the skin was completely bleached within 3 h with blue light only Rebound occurred which

    Original URL path: http://www.clinlab.ru/tm/bilirub/MYARA.HTM (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    pigments on transcutaneous bilirubinometer readings we measured the effect of bilirubin melanin and oxyhemoglobin solutions on transcutaneous bilirubinometer readings in vitro Our results showed that the variability of the readings in vitro was related to the instrument s non linear

    Original URL path: http://www.clinlab.ru/tm/bilirub/68.%20Onks.htm (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    attempts to reduce the number of serum bilirubin determinations to be performed in the future We did a correlation coefficient between serum bilirubin and five measurements of transcutaneous bilirubin levels in a group of 60 term newborns and 60 preterm newborns obtaining a value of 0 84 in both groups The results were also considered from an analytical point of view where the ability of the test to predict an

    Original URL path: http://www.clinlab.ru/tm/bilirub/69.%20Pall.htm (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    TcBM were performed in 124 Chinese newborns with hyperbilirubinemia and jaundice in evidence The effect of pathologic factors on the relationship between TcBM readings and total serum bilirubin SB levels was analyzed by multiple regression The results of regression showed that the relationship between TcBM readings and total SB levels was affected by anemia phototherapy ABO and Ph hemolytic disease and premature Multiple stepwise regression showed that after adjusting for

    Original URL path: http://www.clinlab.ru/tm/bilirub/72.%20Peng.htm (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    life and nurses must possess accurate neonatal assessment skills Unlike nurses who work in hospital settings those who provide home care do not have ready access to colleagues for consultation and validation of assessments The result of unrefined assessment skills of nurses may be requests for unnecessary invasive procedures for infants and consequently monetary charges to patients for unnecessary lab work A quasi experimental design was used to determine whether

    Original URL path: http://www.clinlab.ru/tm/bilirub/74.%20Ruchala.htm (2014-12-29)
    Open archived version from archive

  • Abstracts - Problem of Transcutaneous Bilirubinometry
    in many cases difficult to resolve despite of current advances in exploration techniques echography specially In this review the significance of each method is discussed The significance of clinical data as a first diagnostic stage is analyzed Afterwards according to

    Original URL path: http://www.clinlab.ru/tm/bilirub/75.%20Salmer.htm (2014-12-29)
    Open archived version from archive